Glow-worm Xtrafast 96 120 Fault codes & diagnostics

23 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 35-37 kW 2001-present
GC Number 47-047-25
Download the Glow-worm Xtrafast 96 120 manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 20 High 1 Medium 1 Low

All 23 documented codes

Tap any card for details

0 bar

Your boiler has lost its water pressure, which means it has stopped running to protect the internal components from damage.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually a silver flexible hose) under the boiler.
  2. Slowly open the one or two small taps on the hose until you hear water flowing.
  3. Watch the pressure gauge until it reaches between 1.0 and 1.5 bar, then close the taps tightly.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure relief valve

Related codes

02

Your boiler has stopped working because the fan system cannot properly clear waste gases or bring in fresh air to burn fuel safely.

High Engineer only £120-280

Parts commonly replaced

  • Fan motor
  • Air pressure switch
  • Venture tube

Related codes

04

Your boiler is failing to light the flame needed to heat your water and radiators.

High DIY-safe £100-280

What to check first

  1. Check that your gas pre-payment meter hasn't run out of credit
  2. Ensure other gas appliances in your home, like a hob, are receiving gas
  3. Press the 'Reset' button on the boiler control panel to see if it restarts

Parts commonly replaced

  • Ignition Electrode
  • Flame Sensing Electrode
  • Gas Valve

Related codes

05

Your boiler has got too hot and has shut itself down as a safety precaution to prevent damage.

High DIY-safe £120-350

What to check first

  1. Check that all radiator valves are fully open (especially TRVs)
  2. Ensure there is enough water pressure in the system (typically 1.0 to 1.5 bar)
  3. Press the reset button once the boiler has had time to cool down

Parts commonly replaced

  • Overheat Thermostat
  • Circulation Pump
  • Main Heat Exchanger

Related codes

06

Your boiler has detected a problem with the internal sensor that monitors the temperature of your heating water, meaning the system cannot run safely.

High Engineer only £90-160

Parts commonly replaced

  • Central heating NTC thermistor
  • Wiring harness connectors

Related codes

07

Your boiler has stopped providing hot water because the internal sensor responsible for measuring water temperature has either failed or has a loose connection.

Medium Engineer only £90-160

Parts commonly replaced

  • DHW Thermistor (NTC Sensor)
  • Wiring Harness

Related codes

08

Your boiler has lost its ability to monitor the temperature of the stored hot water, meaning it cannot heat your water reliably or safely.

High Engineer only £120-190

Parts commonly replaced

  • Storage vessel NTC thermistor
  • Wiring harness

Related codes

09

Your boiler's internal sensor is struggling to accurately read the water pressure, which prevents the system from operating safely.

High Engineer only £120-210

Parts commonly replaced

  • System pressure sensor
  • Sensor wiring harness

Related codes

10

Your boiler has detected that the fan, which safely removes waste gases from the appliance, is not spinning correctly or has lost communication with the main control board.

High Engineer only £250-£450

Parts commonly replaced

  • Fan motor assembly
  • Main PCB
  • Air pressure switch

Related codes

Showing 11–20 of 23
12

Your boiler's control panel and its internal computer are having trouble communicating with each other, preventing the unit from starting.

High Engineer only £180-350

Parts commonly replaced

  • User Interface PCB
  • Main Control PCB
  • Connection Wiring Loom
13

Your boiler's internal computer has developed a fault and can no longer control the system safely.

High Engineer only £280-£450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Wiring Harness

Related codes

14

Your boiler has shut down because a sensor has detected that it is getting far too hot, likely due to a circulation problem.

High Engineer only £120-£350

Parts commonly replaced

  • Circulation Pump
  • Flow NTC Sensor
  • Main Heat Exchanger

Related codes

15

Your boiler is unable to correctly control the supply of gas it needs to create a flame, causing the system to shut down for safety.

High Engineer only £180-350

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

16

Your boiler has detected that gas is leaking through its internal safety valves, meaning the system is potentially unsafe and must be shut down immediately.

Emergency Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • Gas valve solenoid
  • PCB

Related codes

17

Your boiler is struggling because the electricity supply it is receiving is weaker than the level it needs to operate safely.

High Engineer only £120-250

Parts commonly replaced

  • Main printed circuit board
  • Transformer

Related codes

20

Your boiler's internal computer parts are struggling to talk to each other, which prevents the system from starting up normally.

High Engineer only £180-450

Parts commonly replaced

  • Main PCB
  • User Interface Display PCB
  • Wiring Harness

Related codes

21

Your boiler has detected that there is not enough water pressure inside the system to operate safely.

High DIY-safe £80-150

What to check first

  1. Locate the filling loop (usually a silver braided hose with one or two valves) located underneath your boiler.
  2. Slowly open the valve(s) to allow water to enter the system while watching the pressure gauge on the front of the boiler.
  3. Close the valve(s) firmly once the needle reaches 1.5 bar, then check the boiler display to see if the fault has cleared.

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Pressure sensor
F0

Your boiler has stopped working because the water pressure is too low for the system to run safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually a silver flexible hose) underneath the boiler.
  2. Slowly open the one or two taps/levers on the filling loop to allow water into the system.
  3. Watch the pressure gauge until it reaches between 1.0 and 1.5 bar, then close the taps fully.

Parts commonly replaced

  • Filling loop
  • Pressure sensor
  • Expansion vessel

Related codes

F9

Your boiler has detected an issue with how it monitors water levels, meaning it cannot confirm there is enough water to safely provide heating or hot water.

High Engineer only £140-£260

Parts commonly replaced

  • Water pressure sensor
  • Pressure sensor wiring loom
  • Main PCB

Related codes

Showing 21–23 of 23
F12

Your boiler's control panel and its internal computer are failing to talk to each other, meaning the unit cannot receive instructions to operate.

High Engineer only £150-300

Parts commonly replaced

  • User Interface PCB
  • Main Control PCB
  • Wiring harness

Related codes

Pictogram of a spark

Your boiler is failing to light because it isn't receiving a gas supply or cannot detect a flame.

High DIY-safe £100-£280

What to check first

  1. Check that your gas emergency control valve (usually by the meter) is in the 'on' position.
  2. If you have a pre-payment meter, check that you have sufficient credit.
  3. Check if other gas appliances in the home, such as a hob, are working correctly.
  4. Press and hold the reset button for five seconds to see if the boiler restarts.

Parts commonly replaced

  • Gas Valve
  • Ignition Electrode
  • PCB

Related codes

Telephone symbol

Your boiler has detected an internal error that prevents it from operating normally, and it requires a professional to identify the specific issue.

High Engineer only £120-250

Parts commonly replaced

  • Main PCB
  • Pressure Sensor
  • NTC Thermistor

Related codes