Vaillant ecoTEC Plus 836 Fault codes & diagnostics

110 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 36 kW 2023-present
GC Number 47-044-94
Download the Vaillant ecoTEC Plus 836 manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
12 Emergency 84 High 13 Medium 1 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-044-94 ecoTEC plus 836 VUW 30/36CS/1-5 (N-GB) 2023–present

All 110 documented codes

Tap any card for details

con

Your boiler's control panel and its internal computer are not talking to each other, meaning the unit cannot receive instructions to provide heat or hot water.

High Engineer only £180-450

Parts commonly replaced

  • Main PCB
  • Display Interface Module
  • Wiring harness

Related codes

F.000

Your boiler has lost the ability to read the temperature of the water inside it, so it has shut down as a precaution to prevent overheating.

High Engineer only £120-200

Parts commonly replaced

  • NTC Flow Temperature Sensor
  • Wiring harness

Related codes

F.001

Your boiler has lost its connection to a sensor that measures the temperature of water returning to it, meaning it cannot safely regulate how much it heats your home.

High Engineer only £120-200

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

F.002

Your boiler is struggling to detect the temperature of your hot water supply because of a faulty connection or sensor, which will likely prevent you from getting hot water.

High Engineer only £120-220

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC temperature sensor
  • Wiring harness

Related codes

F.003

Your boiler is having trouble communicating with the temperature sensor in your hot water tank, which means it may struggle to heat your water properly.

Medium Engineer only £120-220

Parts commonly replaced

  • Cylinder NTC temperature sensor
  • Wiring harness

Related codes

F.010

Your boiler has lost its connection to the sensor that measures water temperature, so it has safely shut down to prevent overheating.

High Engineer only £120-220

Parts commonly replaced

  • NTC flow temperature sensor
  • Wiring harness

Related codes

F.011

Your boiler has lost its connection to a sensor that measures the temperature of the water coming back into the system, which is preventing it from running safely.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

F.012

Your boiler is struggling to accurately measure the temperature of the water it is heating for your taps, meaning you likely have no hot water available.

High Engineer only £120-200

Parts commonly replaced

  • Domestic hot water NTC sensor
  • Wiring harness

Related codes

F.013

Your boiler has lost the connection to the temperature sensor inside your hot water tank, meaning it cannot accurately monitor your hot water levels.

Medium Engineer only £120-220

Parts commonly replaced

  • NTC cylinder sensor
  • Wiring harness

Related codes

F.020

Your boiler has detected that the water pressure inside the system has dropped too low, so it has safely shut itself down to prevent any damage.

High DIY-safe £80-150

What to check first

  1. Locate the filling loop (a silver flexible hose or internal key) underneath your boiler.
  2. Slowly open the valve to allow water to enter the system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Close the valve tightly and check that the error code clears from the display.

Parts commonly replaced

  • Pressure sensor
  • Filling loop
  • Expansion vessel

Related codes

Showing 11–20 of 110
F.022

Your boiler has stopped working because the water pressure inside the system has dropped too low to operate safely.

High DIY-safe £0-£120

What to check first

  1. Locate the filling loop (usually two silver taps connected by a flexible braided hose underneath the boiler).
  2. Open the taps slowly to let water enter the system until the pressure gauge on the front of the boiler reads between 1.0 and 1.5 bar.
  3. Close both taps tightly to stop the flow and check for any leaks.

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Pressure sensor

Related codes

F.023

Your boiler is struggling because there is trapped air or a blockage preventing water from circulating properly around your heating system.

High DIY-safe £100-250

What to check first

  1. Check your boiler's pressure gauge and top it up to 1.5 bar if it is below 1 bar
  2. Bleed all the radiators in your home starting from the lowest floor to the highest
  3. Restart the boiler once the system has been bled and repressurised

Parts commonly replaced

  • Central heating pump
  • System filter
  • Diverter valve

Related codes

F.024

Your boiler has detected trapped air inside the system, which is causing the water temperature to rise much faster than it safely should.

High DIY-safe £90-180

What to check first

  1. Check your boiler pressure gauge to ensure it is between 1.0 and 1.5 bar.
  2. Bleed all radiators in your home starting from the lowest floor to the highest to remove trapped air.
  3. Re-pressurise the system to the correct level if the pressure dropped after bleeding the radiators.

Parts commonly replaced

  • Automatic air vent
  • Pump
  • System pressure sensor

Related codes

F.025

Your boiler has detected that the exhaust gases are getting much hotter than they should be, or there is an issue with the electrical connection monitoring these temperatures.

High Engineer only £150-300

Parts commonly replaced

  • Flue gas temperature sensor
  • Wiring harness
  • PCB

Related codes

F.027

Your boiler has detected that gas might be leaking internally while the burner is meant to be off, so it has shut down to keep your home safe.

Emergency Engineer only £200-450

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.028

Your boiler is failing to light because it cannot detect a flame, meaning you currently have no heating or hot water.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead
  • Printed Circuit Board (PCB)

Related codes

F.029

Your boiler has stopped working because it cannot detect a flame, most likely because it is not receiving enough gas to stay lit.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Ignition electrode
  • Printed Circuit Board

Related codes

F.032

Your boiler has detected that the internal fan responsible for venting exhaust gases safely is not spinning at the correct speed, so it has shut down to prevent unsafe operation.

High Engineer only £250-450

Parts commonly replaced

  • Fan unit
  • PCB (Printed Circuit Board)
  • Wiring harness

Related codes

F.035

Your boiler is struggling to breathe because the pipe that vents exhaust gases outside or brings in fresh air is blocked or obstructed.

Emergency Engineer only £120-250

Parts commonly replaced

  • Flue terminal
  • Fan assembly
  • Air pressure switch

Related codes

F.040

Your boiler is struggling to breathe properly because it is detecting trapped exhaust fumes or a blockage in the air intake or flue pipe.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue assembly seals
  • Air intake pipework
  • Gas valve
  • Venturi

Related codes

Showing 21–30 of 110
F.042

Your boiler has lost the electrical connection to the part that manages the gas supply, meaning it cannot safely start up and will stop providing heat and hot water.

High Engineer only £150-250

Parts commonly replaced

  • Gas valve wiring harness
  • Gas valve assembly

Related codes

F.044

Your boiler is struggling to breathe properly, meaning exhaust fumes are getting trapped inside the unit rather than being vented outside.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue seal
  • Gas valve
  • Fan assembly
  • Ignition electrode

Related codes

F.047

Your boiler is struggling to accurately measure the temperature of the water being heated for your taps, which will likely prevent you from getting hot water.

Medium Engineer only £120-220

Parts commonly replaced

  • Domestic hot water sensor
  • Wiring harness

Related codes

F.049

Your boiler's communication system, which allows it to talk to your thermostat and other controls, is currently experiencing a wiring fault or a connection conflict.

High Engineer only £120-250

Parts commonly replaced

  • eBUS PCB
  • Wiring harness
  • External thermostat/controller

Related codes

F.057

Your boiler has detected a failure in its internal combustion safety system and has shut down to prevent unsafe operation.

High Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • PCB (Printed Circuit Board)
  • Ionisation electrode

Related codes

F.061

Your boiler has detected an internal communication error with the gas control system, which prevents it from safely igniting the burner.

High Engineer only £180-350

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Gas Valve Wiring Harness

Related codes

F.062

Your boiler has detected an issue with the valve that controls the gas flow, meaning it cannot safely shut down the flame as intended.

Emergency Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • Printed circuit board

Related codes

F.063

Your boiler's main control computer is experiencing a memory error and can no longer process instructions correctly, meaning the unit will not be able to operate.

High Engineer only £300-500

Parts commonly replaced

  • Main PCB
  • UI PCB

Related codes

F.064

Your boiler's electronic control system is unable to read data from one of its internal sensors, causing it to shut down for safety reasons.

High Engineer only £150-250

Parts commonly replaced

  • NTC sensor
  • Wiring harness
  • Main PCB

Related codes

F.065

Your boiler has detected that its internal computer is getting too hot and has shut itself down to prevent damage to the internal wiring and controls.

High Engineer only £150-350

Parts commonly replaced

  • Main PCB
  • Wiring harness
  • Interface board

Related codes

Showing 31–40 of 110
F.067

Your boiler is confused because it detects a flame when it shouldn't be there, or the sensor that checks for the flame is malfunctioning.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame rectification electrode

Related codes

F.068

Your boiler's main control unit is struggling to correctly detect or manage the burner flame, meaning it will likely shut down to keep you safe.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

F.071

Your boiler is struggling to read its own internal water temperature accurately, so it has stopped working to prevent any potential damage.

High Engineer only £120-220

Parts commonly replaced

  • Flow temperature sensor (NTC)
  • Wiring harness

Related codes

F.072

Your boiler has detected that the water temperature readings are inconsistent, which stops it from heating your home safely.

High Engineer only £150-250

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness

Related codes

F.074

Your boiler is struggling to read how much water is inside the system because the sensor that monitors pressure has lost its electrical connection.

High Engineer only £120-220

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.075

Your boiler is struggling to confirm that water is flowing correctly through the system because a sensor is failing to detect the expected pressure change.

High Engineer only £150-250

Parts commonly replaced

  • Water pressure sensor

Related codes

F.076

Your boiler has detected that a safety sensor meant to prevent overheating has lost its connection, so it has safely shut down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • Wiring harness
  • Overheat thermostat
  • Main PCB

Related codes

F.077

Your boiler has detected an issue with the exhaust system that prevents it from safely venting gases, so it has stopped working to protect you.

High Engineer only £150-300

Parts commonly replaced

  • Flue non-return flap
  • Condensate pump
  • PCB

Related codes

F.078

Your boiler has detected that an electronic component inside the unit is not the correct model or version required for this specific system.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • UI Interface Module

Related codes

Showing 41–50 of 110
F.080

Your boiler is struggling to accurately detect the temperature of the water coming into your home, which may prevent your hot water or heating from working correctly.

Medium Engineer only £120-220

Parts commonly replaced

  • Cold water inlet NTC sensor
  • Wiring harness

Related codes

F.081

Your boiler has lost the internal electrical connection needed to heat your hot water tank, meaning you likely have no hot water available.

High Engineer only £120-250

Parts commonly replaced

  • Wiring harness
  • Diverter valve motor
  • Main PCB

Related codes

F.083

Your boiler is failing to heat up because it cannot detect any water movement or temperature change, which usually indicates that your system pressure has dropped too low.

High DIY-safe £80-180

What to check first

  1. Check your boiler's pressure gauge on the front display; it should be between 1.0 and 1.5 bar.
  2. If the pressure is below 1.0 bar, locate the filling loop (usually a silver braided hose under the boiler).
  3. Open the valves on the filling loop to let water into the system until the gauge reaches 1.5 bar, then ensure the valves are fully closed.

Parts commonly replaced

  • System pressure sensor
  • Circulation pump
  • Flow sensor

Related codes

F.084

Your boiler is confused because it is detecting unusual temperature differences between its water pipes, which usually means a sensor is loose, incorrectly fitted, or malfunctioning.

High Engineer only £120-220

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring harness

Related codes

F.085

Your boiler's temperature sensors have been swapped or attached to the wrong pipes, meaning the boiler cannot accurately measure how hot the water is.

High Engineer only £120-200

Parts commonly replaced

  • NTC Sensor
  • Wiring harness

Related codes

F.087

Your boiler is failing to light because the component responsible for creating the ignition spark is not receiving power or is incorrectly plugged in.

High Engineer only £120-250

Parts commonly replaced

  • Ignition lead
  • Ignition transformer
  • Main PCB

Related codes

F.088

Your boiler has lost the electrical signal to the valve that controls the gas supply, meaning it cannot safely start to heat your water or home.

Emergency Engineer only £150-250

Parts commonly replaced

  • Gas valve
  • Wiring harness
  • Main PCB

Related codes

F.089

Your boiler has detected that the internal water pump is not the correct type for this specific model, which prevents it from operating correctly.

High Engineer only £250-450

Parts commonly replaced

  • High-efficiency circulation pump
  • Printed Circuit Board (PCB)

Related codes

F.090

Your boiler has lost the electronic connection to your hot water tank, meaning it cannot detect or manage your hot water supply.

High Engineer only £120-250

Parts commonly replaced

  • Wiring harness
  • Sensor lead
  • Main PCB

Related codes

F.092

Your boiler has not been correctly set up to handle the specific type of gas it is receiving, preventing it from operating safely.

High Engineer only £120-250

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board

Related codes

Showing 51–60 of 110
F.095

Your boiler is struggling to breathe properly because exhaust fumes are getting trapped or blocked, making it unsafe to continue running.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Flue seals
  • Fan

Related codes

F.096

Your boiler is struggling to get enough gas supply to function correctly, causing it to shut down for safety reasons.

Emergency Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Gas meter regulator

Related codes

F.097

Your boiler's internal computer has failed its diagnostic check, meaning it cannot safely control the system.

High Engineer only £300-500

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

F.105

Your boiler's computer has lost the specific internal calibration settings required to mix the gas and air correctly for combustion.

High Engineer only £120-220

Parts commonly replaced

  • Gas valve
  • PCB

Related codes

F.194

Your boiler has detected an internal electrical failure which is preventing it from powering up correctly, meaning it cannot provide heating or hot water.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

F.195

Your boiler is struggling because it is not receiving enough electricity from your home's mains power supply.

High Engineer only £120-250

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring harness
  • External power supply fuse

Related codes

F.196

Your boiler has detected an unstable electricity supply that is higher than the safe limit, causing it to shut down to protect its internal electronics.

High Engineer only £150-350

Parts commonly replaced

  • Main PCB
  • Power supply module

Related codes

F.317

Your boiler is struggling to detect the flow of water needed to heat your taps, which will likely prevent you from getting hot water.

Medium Engineer only £150-250

Parts commonly replaced

  • DHW Flow Sensor
  • Wiring Harness

Related codes

F.318

Your boiler is struggling to switch between heating your radiators and heating your hot water because the internal valve that directs the water flow is not receiving an electrical signal.

High Engineer only £180-350

Parts commonly replaced

  • Diverter valve motor
  • Complete diverter valve assembly
  • Wiring harness

Related codes

F.320

Your boiler's water pump is struggling to circulate water because it is blocked by debris or sludge, which will prevent your heating and hot water from working.

High Engineer only £200-450

Parts commonly replaced

  • Central heating pump
  • Pump head
  • System filter

Related codes

Showing 61–70 of 110
F.321

Your boiler's water circulation pump has stopped working, which means the system cannot push hot water to your radiators or taps.

High Engineer only £250-450

Parts commonly replaced

  • High-efficiency circulation pump
  • Pump wiring harness

Related codes

F.322

Your boiler's water pump has detected it is getting too hot and has automatically shut down to prevent damage.

High Engineer only £250-450

Parts commonly replaced

  • Heating pump
  • Pump module
  • Wiring harness

Related codes

F.323

Your boiler has trapped air inside its main water circulation system, which is preventing the pump from moving water effectively to provide heat or hot water.

High DIY-safe £90-180

What to check first

  1. Check the boiler's pressure gauge and ensure it is between 1.0 and 1.5 bar, topping it up using the filling loop if necessary
  2. Bleed your radiators throughout the home to release any trapped air
  3. Restart the boiler to clear the fault code

Parts commonly replaced

  • Automatic air vent
  • System pump
  • Pressure sensor

Related codes

F.324

Your boiler has lost its connection to the internal water pump, which means it cannot circulate water to provide you with heating or hot water.

High Engineer only £150-250

Parts commonly replaced

  • Pump wiring harness
  • Circulation pump
  • Printed Circuit Board (PCB)

Related codes

F.325

Your boiler is unable to move water around your heating system because the internal pump is stuck or not spinning correctly.

High Engineer only £200-400

Parts commonly replaced

  • High-efficiency pump
  • Pump wiring harness
  • PCB

Related codes

F.326

Your boiler is struggling to switch between heating your radiators and heating your hot water because a key internal valve is stuck or failing.

High Engineer only £200-350

Parts commonly replaced

  • Diverter valve actuator
  • Diverter valve cartridge

Related codes

F.327

Your boiler is confused because it thinks it has been installed without a hot water tank, but it is currently trying to operate as if it should have one.

Medium Engineer only £120-250

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

F.330

Your boiler has detected that the water pump, which is essential for circulating heat around your home, is failing to start correctly.

High Engineer only £180-350

Parts commonly replaced

  • Central heating pump
  • PCB (Printed Circuit Board)
  • Wiring harness

Related codes

F.334

Your boiler's computer system has lost the specific settings that tell it how your exhaust pipe is configured, preventing it from starting up safely.

High Engineer only £100-200

Parts commonly replaced

  • Main PCB

Related codes

F.336

Your boiler has detected that the air intake or exhaust setup does not match its internal settings, meaning it cannot operate safely and has shut down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • Main PCB
  • Air pressure sensor
  • Flue assembly

Related codes

Showing 71–80 of 110
F.337

Your boiler has detected that the flue attachment used to vent exhaust gases does not correctly match the internal configuration of your specific heater model.

High Engineer only £150-300

Parts commonly replaced

  • Flue adaptor
  • Air intake seal
  • PCB

Related codes

F.338

Your boiler's internal settings do not match the way it is connected to its flue pipe, causing it to stop working to prevent unsafe operation.

High Engineer only £120-250

Parts commonly replaced

  • Main printed circuit board (PCB)
  • Air pressure switch
  • Flue sensor

Related codes

F.342

Your boiler is struggling to push the right amount of air through its system to burn gas safely, so it has stopped working to prevent any potential danger.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Venturi

Related codes

F.343

Your boiler has lost the connection to the internal sensor that measures the air flow needed for safe combustion, causing the unit to stop working as a precaution.

High Engineer only £120-250

Parts commonly replaced

  • Air mass flow sensor
  • Wiring harness
  • Printed Circuit Board

Related codes

F.344

Your boiler has lost the digital settings it needs to safely control the flame, meaning it cannot operate until these are reset or the internal hardware is replaced.

High Engineer only £200-450

Parts commonly replaced

  • PCB
  • Ionisation electrode

Related codes

F.347

Your boiler has detected water pooling inside the internal combustion area, which prevents it from firing up safely to protect the system.

High Engineer only £150-300

Parts commonly replaced

  • Condensate trap
  • Flue system seals
  • Heat exchanger gasket

Related codes

F.363

Your boiler's computer screen or main control board is having trouble saving and reading its internal settings, which means the boiler cannot safely operate.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • User Interface Display

Related codes

F.707

Your boiler's control panel has lost its connection to the internal brain, meaning the system cannot communicate or operate safely.

High Engineer only £150-300

Parts commonly replaced

  • UI interface (display module)
  • Main PCB
  • Communication cable

Related codes

F.905

Your boiler has detected an electrical fault in its internal communication system, causing it to shut down to prevent further damage.

High Engineer only £180-350

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring harness
  • Communication interface module

Related codes

L.016

Your boiler has lost its flame while running at a low heat setting, causing it to shut down for safety.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Ignition electrode
  • Burner seal

Related codes

Showing 81–90 of 110
L.022

Your boiler has detected that there is not enough water flowing through the heating system to operate safely.

High DIY-safe £80-250

What to check first

  1. Check that all radiator valves and any external zone valves are fully open
  2. Check your system pressure gauge is between 1 and 1.5 bar
  3. If the pressure is low, use the filling loop to top up the system to the correct level
  4. Bleed any trapped air from your radiators

Parts commonly replaced

  • Central heating pump
  • System pressure sensor
  • Diverter valve

Related codes

L.025

Your boiler is having trouble reading the temperature of the incoming cold water supply, which means it may struggle to provide hot water at the correct temperature.

Medium Engineer only £120-220

Parts commonly replaced

  • Cold water NTC thermistor sensor
  • Wiring harness

Related codes

L.032

Your boiler is struggling to accurately detect the flow of water circulating through your heating system, which means it may prevent the heating or hot water from turning on to protect itself.

High Engineer only £150-250

Parts commonly replaced

  • Flow sensor
  • Wiring harness

Related codes

L.095

Your boiler's gas control mechanism is struggling to adjust correctly, meaning it cannot reliably maintain the flame required to heat your home.

High Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • Main PCB

Related codes

L.096

Your boiler has detected an issue with the internal gas control mechanism, preventing it from starting up safely.

High Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • Main PCB

Related codes

L.097

Your boiler is struggling to mix the right amount of air with its gas supply, which prevents it from burning fuel safely and efficiently.

Emergency Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Air pressure switch
  • Venturi
  • Fan

Related codes

L.105

Your boiler is struggling to remove trapped air from the system, which is preventing it from starting up correctly.

High Engineer only £120-250

Parts commonly replaced

  • Automatic air vent
  • System pump
  • System pressure sensor

Related codes

L.144

Your boiler is struggling to detect the flame needed to heat your water and home, so it has shut down as a safety precaution.

High Engineer only £150-300

Parts commonly replaced

  • Ionisation electrode
  • Ignition lead
  • PCB

Related codes

L.194

Your boiler's main control system has detected a power failure on its internal circuit board, meaning it cannot operate safely and has shut down.

High Engineer only £250-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Power Supply Unit

Related codes

L.195

Your boiler is struggling because the electricity supply feeding it is unstable or dropping below the required voltage level.

Medium Engineer only £120-250

Parts commonly replaced

  • Printed Circuit Board
  • Wiring harness

Related codes

Showing 91–100 of 110
L.196

Your boiler has detected an unstable or too-high electrical voltage coming from your home's mains power supply, causing it to shut down to protect its internal electronics.

High Engineer only £150-350

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Surge protection fuse

Related codes

L.319

Your boiler is struggling to circulate water properly because a safety valve designed to manage internal pressure is stuck or obstructed.

Medium Engineer only £150-250

Parts commonly replaced

  • Bypass valve
  • Circulation pump

Related codes

L.320

Your boiler's water pump is struggling to spin, likely due to debris or inactivity, so the system is currently trying to clear itself to get your heating and hot water back on.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • Pump head

Related codes

L.322

Your boiler has detected that the water circulation pump is getting too hot and has stopped working to protect itself, which means you currently have no heating or hot water.

High Engineer only £250-450

Parts commonly replaced

  • Central heating pump
  • Printed Circuit Board (PCB)

Related codes

L.343

Your boiler has detected an issue with how it measures the amount of air flowing through its internal system, which prevents it from operating safely.

High Engineer only £150-300

Parts commonly replaced

  • Air mass flow sensor
  • Wiring harness
  • PCB

Related codes

N.013

Your boiler's internal sensor that measures water pressure has stopped sending a readable signal, meaning the system cannot accurately monitor its own status.

Medium Engineer only £150-250

Parts commonly replaced

  • Water pressure sensor

Related codes

N.027

Your boiler is struggling to accurately measure the temperature of the water used for your taps and shower, which will likely result in the water being cold or failing to heat up at all.

Medium Engineer only £120-220

Parts commonly replaced

  • Domestic Hot Water NTC Temperature Sensor

Related codes

N.032

Your boiler is struggling to detect the flow of water because of trapped air or a faulty sensor, meaning it cannot reliably heat your home or water.

High Engineer only £150-£250

Parts commonly replaced

  • Flow sensor
  • Wiring harness

Related codes

N.089

Your boiler has identified that the internal water pump currently installed is the wrong model for your specific heater, preventing it from starting up correctly.

High Engineer only £250-400

Parts commonly replaced

  • High-efficiency circulation pump
  • PCB (if sensor calibration is required)

Related codes

N.095

Your boiler is struggling to breathe properly because exhaust fumes are getting trapped or recycled back into the system, causing it to shut down for safety.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue seal
  • Gas valve
  • Air pressure switch
  • Fan

Related codes

Showing 101–110 of 110
N.096

Your boiler is struggling to receive enough gas to heat your home properly and has reached its safety limit trying to compensate.

High Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Gas meter regulator

Related codes

N.097

Your boiler is struggling to breathe because exhaust gases are getting trapped or flowing back into the intake, meaning the system cannot burn fuel safely.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue terminal
  • Fan
  • Air pressure switch
  • Burner seal

Related codes

N.100

Your boiler has lost the connection to the weather sensor outside that tells it how hard to work based on the temperature.

Low Engineer only £120-180

Parts commonly replaced

  • Outdoor temperature sensor
  • Wiring loom

Related codes

N.144

Your boiler is struggling to breathe properly because exhaust fumes are getting trapped or recycled back into the system, which prevents it from igniting safely.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue seal
  • Air intake pipe
  • Ionisation electrode
  • PCB

Related codes

N.194

Your boiler's main electronic control board is failing to receive the power it needs to function, which means the system cannot operate.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Power supply unit

Related codes

N.270

Your boiler is struggling to heat your tap water properly because a small filter inside the unit has become blocked by debris from your water supply.

Medium Engineer only £120-220

Parts commonly replaced

  • Cold water inlet strainer/filter
  • Secondary heat exchanger

Related codes

N.317

Your boiler is having trouble communicating with the part that detects when you turn on a hot water tap, meaning it may fail to provide hot water correctly.

Medium Engineer only £150-250

Parts commonly replaced

  • DHW Flow Sensor
  • Wiring harness

Related codes

N.319

Your boiler is struggling to circulate water properly because an internal valve is blocked with debris, which may stop your heating or hot water from working effectively.

High Engineer only £180-350

Parts commonly replaced

  • Bypass valve
  • Diverter valve cartridge
  • Central heating filter

Related codes

N.324

Your boiler has lost its connection to the water pump, which means it cannot circulate water to provide you with heating or hot water.

High Engineer only £150-250

Parts commonly replaced

  • Pump wiring harness
  • Central heating pump

Related codes

N.343

Your boiler's air sensor is disconnected or faulty, which prevents it from correctly measuring the air flow needed to burn fuel safely.

High Engineer only £120-250

Parts commonly replaced

  • Air mass flow sensor
  • Wiring harness

Related codes

171 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

D.000 Diagnostic Your boiler is currently set to run at a lower power level than its maximum capacity to save energy or match your home's heat demand. D.001 Diagnostic Your boiler is signalling that the internal water pump has been running for longer than expected, which usually indicates the system is struggling to circulate water effectively. D.002 Diagnostic Your boiler is currently taking a mandatory rest period to prevent the system from overheating, which is a normal part of its operation. D.003 Diagnostic Your boiler is simply reporting the current temperature of the hot water it is producing, which is a normal status reading rather than a breakdown. D.004 Diagnostic Your boiler is struggling to accurately measure the temperature of the water stored in your hot water cylinder. D.005 Diagnostic This code is not actually an error; it is a status message showing the current temperature your boiler is aiming for to heat your radiators. D.006 Diagnostic Your boiler is simply displaying the current temperature setting for your hot water, which is a normal status message rather than an actual fault. D.008 Diagnostic Your boiler is currently receiving a signal from your wall thermostat telling it to switch on, but the boiler is essentially just reporting that this 'on' status is active. D.009 Diagnostic Your boiler is struggling to communicate correctly with your thermostat or external controls, which may prevent your heating from turning on as expected. D.010 Diagnostic Your boiler is signalling that the internal water pump is not running as expected, which prevents heat from moving around your home. D.011 Diagnostic Your boiler is signalling that the external pump, which helps move hot water around your home's pipes, is currently active. D.012 Diagnostic Your boiler is currently focused on heating the water stored in your hot water cylinder, which is a normal part of its operation. D.013 Diagnostic Your boiler is struggling to push water around your heating system, which means it cannot circulate heat to your radiators or taps effectively. D.015 Diagnostic Your boiler is reporting a communication error regarding how fast the water pump is moving inside the system, which typically means the boiler is struggling to circulate water effectively. D.016 Diagnostic Your boiler is struggling to communicate with your wall-mounted heating controller, so it has stopped firing up because it isn't receiving a clear signal to start. D.017 Diagnostic Your boiler is having difficulty communicating with your heating controls or thermostat, which may prevent your radiators from switching on or off as expected. D.018 Diagnostic Your boiler is simply indicating that the internal water pump is currently running to move heat around your radiators. D.020 Diagnostic Your boiler is currently displaying a status code indicating that the maximum temperature setting for your hot water has been adjusted or configured. D.021 Diagnostic Your boiler is simply indicating that the 'warm start' feature, which keeps the internal water hot for faster taps, is currently active. D.022 Diagnostic Your boiler is currently working exactly as it should and is simply letting you know it has detected a request to heat your hot water. D.023 Diagnostic Your boiler is currently operating normally and is simply confirming that it has received a request to provide heating or hot water. D.025 Diagnostic Your boiler has received a signal requesting hot water and is currently preparing to heat it up, which is a normal part of its standard operation. D.026 Diagnostic Your boiler is struggling to communicate with an external accessory, such as a heating programmer or a smart thermostat, which is causing it to pause normal operation. D.027 Diagnostic Your boiler is having trouble communicating with an add-on device, such as an external pump or a remote timer unit, that is wired into the system. D.028 Diagnostic Your boiler has detected an issue with an external add-on component, such as an external pump or a heating control module, that it is trying to communicate with. D.029 Diagnostic Your boiler is struggling to circulate enough water through your radiators, which prevents it from heating your home efficiently. D.031 Diagnostic Your boiler is struggling to automatically top up its own water pressure levels, which usually happens because the system detects a leak or the filling device has become stuck. D.033 Diagnostic Your boiler is struggling to keep its internal fan spinning at the correct speed required to safely vent exhaust gases, preventing it from firing up properly. D.034 Diagnostic Your boiler is having trouble detecting the speed of its internal fan, which is preventing it from igniting safely. D.035 Diagnostic Your boiler is struggling to direct heat between your radiators and your hot water taps because a valve inside the system is stuck or failing to move. D.036 Diagnostic Your boiler is struggling to detect the water flowing through it, which is preventing your hot water from heating up properly. D.039 Diagnostic Your boiler is struggling to accurately read the temperature of the incoming cold water, which may cause your hot water to fluctuate in temperature. D.040 Diagnostic Your boiler is struggling to accurately read or communicate the temperature of the water flowing through the system. D.041 Diagnostic Your boiler is struggling to detect the temperature of the water coming back into the system, which can cause it to stop working correctly or shut down to protect itself. D.043 Diagnostic Your boiler is displaying a status code relating to the internal setting that determines how hard it works to heat your home based on the outside temperature. D.045 Diagnostic Your boiler is receiving a signal that the external weather sensor or internal temperature setting is slightly out of its expected range, which may lead to your radiators not reaching the temperature you have set on your thermostat. D.047 Diagnostic Your boiler is struggling to read the temperature from the sensor installed outside your home, so it is using a default setting to keep your heating running. D.052 Diagnostic Your boiler is struggling to correctly adjust the internal gas flow, which is preventing it from lighting or maintaining a steady flame. D.058 Diagnostic Your boiler is currently detecting that the water coming from your solar heating system is not hot enough, so it is temporarily heating it further to ensure you have hot water. D.060 Diagnostic Your boiler has detected that it has overheated multiple times in the past, suggesting that your heating system may be struggling to circulate water properly. D.061 Diagnostic Your boiler has failed to start up several times in a row, so it has locked itself out to prevent potential safety issues. D.062 Diagnostic Your boiler is currently operating in an energy-saving night mode, meaning it has intentionally reduced its output to save fuel while you are likely asleep. D.064 Diagnostic Your boiler is taking slightly longer than normal to light the flame, which might mean it just needs a routine service to clean the internal parts. D.065 Diagnostic Your boiler has failed to light the flame after several attempts, so it has stopped trying to prevent gas from building up inside. D.066 Diagnostic Your boiler is currently trying to keep a small amount of water pre-heated so you get hot water faster when you turn on the tap. D.067 Diagnostic Your boiler is perfectly fine; it is currently in a brief, automatic resting phase to prevent excessive wear and tear before it fires up again. D.068 Diagnostic Your boiler has failed to start its flame on the first try multiple times in a row, meaning it currently cannot heat your water or home. D.069 Diagnostic Your boiler is failing to light because it has repeatedly tried and failed to ignite the gas safely. D.070 Diagnostic Your boiler is struggling to switch between heating your radiators and heating your hot water because the internal diverter valve is not moving into the correct position. D.071 Diagnostic Your boiler is temporarily limiting the heat of the water it produces to protect the system from reaching unsafe temperatures. D.072 Diagnostic Your boiler is simply finishing a standard cooling process after heating up your hot water tank, and this is a normal operational status rather than a fault. D.073 Diagnostic Your boiler is having a minor communication issue with the sensor that maintains the temperature of the internal hot water store. D.074 Diagnostic Your boiler is currently running a routine automated cycle to heat your hot water cylinder to a high temperature to ensure it remains hygienic and free from bacteria. D.075 Diagnostic Your boiler has timed out while trying to heat your hot water cylinder, meaning it couldn't reach the required temperature within the allotted time. D.077 Diagnostic Your boiler is currently running at its absolute maximum capacity to heat your water, which is a normal status message rather than an actual fault. D.078 Diagnostic Your boiler is noting that the temperature setting for your hot water is currently at its maximum allowed limit, which is a status message rather than a breakdown. D.080 Diagnostic This code is simply an information display showing the total number of hours your boiler has spent running the heating system; it is not an error and requires no action. D.081 Diagnostic This code is simply an information display showing the total number of hours your boiler has spent actively heating your hot water, rather than a fault with the system. D.082 Diagnostic Your boiler is simply letting you know that it is currently in the process of starting up its burner to provide heating for your home. D.083 Diagnostic Your boiler is currently just running a normal internal test to ensure the hot water system is working correctly, so there is no need for alarm. D.084 Diagnostic Your boiler is simply reminding you that it is due for its scheduled annual maintenance service. D.085 Diagnostic Your boiler is currently set to its minimum operating power, which often happens during routine system checks or when the boiler is adjusting itself to match your current heating needs. D.088 Diagnostic Your boiler is struggling to detect enough water flowing through it to safely start heating your hot water taps. D.090 Diagnostic Your boiler is having trouble communicating with an external control device like a thermostat or smart home system. D.091 Diagnostic Your boiler is struggling to receive a time signal from a radio transmitter, but this is a minor background issue that will not affect your heating or hot water. D.092 Diagnostic Your boiler is struggling to communicate correctly with the external hot water storage cylinder, which means you may experience issues with your hot water supply. D.093 Diagnostic Your boiler has lost its unique identity code, meaning it does not know which specific model it is or how to operate your heating system correctly. D.094 Diagnostic This code is not a fault, but rather a system confirmation message indicating that your boiler's internal error memory has been successfully wiped. D.095 Diagnostic Your boiler is displaying its internal software version, which is an informational status message rather than a breakdown. D.096 Diagnostic Your boiler has lost its specific configuration settings and needs to be re-calibrated by a professional. D.098 Diagnostic Your boiler is having trouble recognising a key internal communication component, which is preventing it from starting up correctly. D.124 Diagnostic Your boiler is simply displaying a status message indicating it is currently operating in its energy-saving 'SmartECO' mode, which is perfectly normal behavior. D.125 Diagnostic Your boiler is struggling to accurately detect or manage the temperature of the hot water being sent to your taps or shower. D.128 Diagnostic Your boiler is temporarily limiting its output because the water flowing through your heating system is not circulating effectively or is not reaching the required temperature. D.129 Diagnostic Your boiler is struggling to register that you are requesting hot water, meaning it may not trigger the burner to heat your taps or shower correctly. D.145 Diagnostic Your boiler has detected a blockage in the pipes that bring in fresh air or push out exhaust gases, so it has safely shut down to prevent unsafe operation. D.146 Diagnostic Your boiler has reached its internal limit for ignitions and is prompting a routine service check of the ignition electrode to ensure it continues to light safely. D.147 Diagnostic Your boiler has detected an issue with the sensor responsible for checking that the burner is operating correctly, preventing it from starting safely. D.156 Diagnostic Your boiler is currently set to a configuration mode that is waiting for a formal setup process to be completed, which prevents it from firing up. D.157 Diagnostic Your boiler is currently unable to identify what type of gas it should be using, which prevents it from igniting safely. D.158 Diagnostic Your boiler is having difficulty balancing the mix of gas and air required for efficient and safe combustion. D.159 Diagnostic Your boiler is currently in a temporary waiting period to prevent it from cycling on and off too rapidly, which is a normal safety feature to protect internal parts. D.160 Diagnostic Your boiler is struggling to accurately read or maintain the required internal water pressure needed to run efficiently. D.161 Diagnostic Your boiler is simply reminding you that it is time for its annual safety service. D.162 Diagnostic Your boiler is struggling to communicate correctly with your outdoor temperature sensor, meaning it cannot automatically adjust your heating based on the weather outside. D.163 Diagnostic Your boiler is having trouble communicating with an extra piece of equipment, such as an external pump or a timer, that has been connected to it. D.164 Diagnostic Your boiler is currently identifying the specific way its exhaust pipe is set up, which is a normal part of the system's configuration process rather than a breakdown. D.166 Diagnostic Your boiler's internal computer is struggling to read data from its sensors, which prevents it from operating safely and efficiently. D.167 Diagnostic Your boiler is having difficulty communicating with the hot water storage cylinder, which means it may not be able to heat your water supply properly. D.170 Diagnostic Your boiler is currently stuck in a specific operational mode while it attempts to communicate with an external control system, meaning it is not responding to your heating or hot water requests. D.171 Diagnostic Your boiler is struggling to detect the correct water pressure level internally, which is preventing it from starting up reliably. D.172 Diagnostic Your boiler is struggling to accurately measure or balance the temperature difference between the water leaving the unit and the water returning to it. D.173 Diagnostic Your boiler has detected that the water pressure inside your heating system has dropped too low to operate safely. D.174 Diagnostic Your boiler has detected that the water pressure inside the heating system has risen beyond the safe operating limit. D.175 Diagnostic Your boiler has detected that the water pump is not moving water around the system correctly, which prevents your radiators or hot water from working properly. D.182 Diagnostic Your boiler is having difficulty communicating with its internal gas control system, which prevents it from igniting or maintaining a steady flame. D.185 Diagnostic Your boiler's internal computer is currently struggling to recognise its own setup, which is preventing it from starting up correctly. D.186 Diagnostic Your boiler is detecting an issue with the air intake or exhaust system that is shared with other properties or units. D.187 Diagnostic Your boiler is currently in a setup mode and is waiting for you or your engineer to confirm the specific flue pipe configuration installed in your home. I.003 Diagnostic Your boiler is simply reminding you that it is time for its annual safety service to keep it running efficiently and safely. I.020 Diagnostic Your boiler has detected that the water pressure inside your heating system has dropped too low to operate safely. I.144 Diagnostic Your boiler's flame sensor is showing signs of wear and age, meaning it may soon struggle to reliably detect the flame to keep the burner running. P.000 Diagnostic Your boiler is currently running a routine air-removal cycle and will resume normal operation automatically once finished. P.2 Diagnostic Your boiler is currently running a background self-test to check it can operate safely at its lowest power setting. P.008 Diagnostic Your boiler is currently running its automated process to fill the system with water, which is a normal part of its maintenance routine. S.0 Status Your boiler is working perfectly fine and is simply in standby mode because your thermostat is not currently asking for the heating to be turned on. S.000 Status Your boiler is currently in standby mode because it has not been asked to provide any heating or hot water at this time. S.1 Status Your boiler is preparing to ignite but is stuck at the stage where the internal fan is spinning up to clear the combustion chamber. S.001 Status Your boiler is simply preparing to heat your home and is checking its internal systems before igniting, which is a normal part of its startup process. S.2 Status Your boiler is currently moving water through the system after a heating or hot water cycle to cool down the internal components safely. S.002 Status Your boiler is perfectly healthy and is simply preparing itself to start warming your radiators. S.003 Status Your boiler is operating normally and is currently firing up to provide central heating. S.4 Status Your boiler is operating normally and is currently in the process of starting up the burner to provide heat or hot water. S.004 Status Your boiler is working exactly as it should and is currently heating your home. S.005 Status Your boiler is operating normally and is simply running a short cool-down cycle after finishing its heating task. S.006 Status Your boiler is operating normally and is currently in a standard cooling-down phase after finishing a heating cycle. S.7 Status Your boiler is briefly keeping the internal pump running to safely circulate and dissipate leftover heat after you have finished using your heating or hot water. S.007 Status Your boiler is operating normally and is currently running its internal pump to circulate warm water through your radiators or to cool itself down. S.008 Status Your boiler is currently in a brief, normal cooling-down period between heating cycles to prevent excessive wear and tear on its parts. S.009 Status Your boiler is performing a routine, automatic internal maintenance check to calibrate its sensors for optimal performance. S.10 Status Your boiler is simply letting you know that it is currently busy heating up water for your taps or shower. S.010 Status Your boiler is simply currently in standby mode because no taps or showers are calling for hot water. S.11 Status Your boiler is simply preparing its internal airflow to heat your water, which is a normal part of its startup process and not an error at all. S.011 Status Your boiler is simply letting you know that it has received a request for hot water and is starting its normal process to heat it up. S.012 Status Your boiler is simply preparing to deliver hot water to your taps or shower, and this is a normal operating status rather than a fault. S.013 Status Your boiler is simply letting you know that it is currently heating up water because you have a hot tap turned on. S.014 Status Your boiler is working exactly as it should be to heat the water for your taps or shower. S.15 Status Your boiler is simply performing a routine cooling-down process after you last used hot water, and there is no fault with your system. S.015 Status Your boiler is currently working correctly, simply letting you know that it is finishing up the process of providing hot water to your taps or shower. S.016 Status Your boiler is currently operating normally as it finishes cooling down after you have used the hot water taps. S.17 Status Your boiler is simply finishing its cooling cycle after you have finished using hot water, and no action is required. S.017 Status This is not an error code, but rather a status message indicating that your boiler is currently running normally to provide you with hot water. S.019 Status Your boiler is simply performing a routine, automatic internal maintenance check while you have the hot water running, and it is completely normal. S.20 Status Your boiler is not broken; it is simply letting you know that it has received a request to provide hot water and is currently preparing to deliver it. S.020 Status Your boiler is currently in standby mode because it is not receiving a signal to heat your hot water at this moment. S.021 Status Your boiler is currently working normally to heat your hot water tank. S.022 Status Your boiler is currently heating the water stored in your hot water cylinder, which is a normal part of its standard operation. S.023 Status Your boiler is currently heating the water stored in your hot water tank and is working exactly as it should. S.024 Status Your boiler is currently working correctly to heat the water stored in your hot water tank. S.025 Status Your boiler is currently busy heating your hot water storage tank and is running its internal systems to ensure the water is brought up to the correct temperature. S.026 Status Your boiler is currently heating your hot water storage tank and finishing its safety cooling cycle, which is a normal part of its operation. S.027 Status Your boiler is currently busy heating your hot water storage tank and is temporarily diverting energy to finish that process. S.028 Status Your boiler is currently waiting for a short period before it restarts to heat your hot water, which is a normal part of its internal safety cycle. S.029 Status Your boiler is performing a normal, automatic maintenance check on its internal sensors while heating your hot water tank, so there is no need for concern. S.030 Status Your boiler is currently in standby mode because it is not receiving a signal from your thermostat to turn on the heating. S.031 Status Your boiler is currently in standby mode because it is not being asked to provide any heating or hot water at this moment. S.032 Status Your boiler is struggling to keep the internal fan running at the correct speed and has paused to reset itself. S.034 Status Your boiler is temporarily preventing its internal pipes from freezing by running the pump, and this is a normal safety feature during cold weather. S.039 Status Your boiler is temporarily waiting to restart because an external safety device, such as a floor thermostat or a condensate pump, has signalled that it needs to pause operation. S.041 Status Your boiler has detected that the water pressure inside your heating system is currently too high, which may cause it to stop working to protect itself. S.042 Status Your boiler is temporarily waiting for an external accessory, such as a condensate pump or flue flap, to signal that it is ready for operation. S.054 Status Your boiler is temporarily waiting because the water pressure inside the heating system has dropped too low. S.057 Status Your boiler is currently taking a short break to recalibrate its combustion settings and will usually resume normal operation automatically once the waiting period ends. S.059 Status Your boiler is temporarily preventing itself from firing up because it cannot detect enough water flowing through the system to heat it safely. S.088 Status Your boiler is currently running an automated air-removal cycle to clear trapped air from the system, which is a normal process after maintenance or a power restart. S.091 Status Your boiler is currently stuck in a factory demonstration mode, which prevents it from firing up to provide your home with heating or hot water. S.092 Status Your boiler is currently running an automatic internal check to ensure the water is flowing through the system correctly. S.093 Status Your boiler is currently unable to perform an automatic safety check on its exhaust gases, likely because it is not running in a mode that allows this test. S.096 Status Your boiler is currently performing an automatic internal check on its temperature sensors and has temporarily paused heating to complete the process. S.097 Status Your boiler is currently running a quick internal health check on its water pressure sensor and has paused heating and hot water to complete this process. S.098 Status Your boiler is currently performing an automatic internal diagnostic check on its temperature sensors and has temporarily paused heating and hot water to complete this process. S.109 Status Your boiler has temporarily stopped working because it has entered a standby mode, usually while it waits for a signal from your thermostat or because it needs to take a short break before restarting. S.175 Status Your boiler is currently running a setup program and is temporarily pausing normal operation while it completes its automated configuration. S.199 Status Your boiler is currently performing an automatic top-up of its internal water pressure, which is a normal self-maintenance process. S.326 Status Your boiler is currently running a routine internal diagnostic check on its internal water flow components. S.328 Status Your boiler is signalling that an external water pump, which is not actually connected to the system, is trying to run constantly. S.335 Status Your boiler is currently performing a safety check to ensure that air and exhaust fumes are moving through the flue pipe correctly. S.341 Status Your boiler has been running for a long time at a low level to keep the house warm and is automatically taking a brief rest to avoid overheating. S.599 Status Your boiler has detected an internal software or communication error that is preventing it from operating correctly. T.001 Diagnostic Your boiler is struggling to circulate water properly, which means it cannot deliver heating or hot water to your home. T.007 Diagnostic Your boiler is simply indicating that it is running at its absolute minimum heat output to maintain the current temperature.