Vaillant ecoTEC Plus 938 Fault codes & diagnostics

53 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 38 kW 2012-2017 Discontinued
GC Numbers 47-044-6141-044-61

Replaced by: ecoTEC Plus 836

Download the Vaillant ecoTEC Plus 938 manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
4 Emergency 45 High 3 Medium 1 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-044-61 ecoTEC plus 938 H combi A VUI GB 386/5-5 A 2015–2017
41-044-61 ecoTEC plus 615 VU GB 156/5-5 2012–2015

All 53 documented codes

Tap any card for details

con

Your boiler's control panel and its internal computer are not talking to each other, meaning the unit cannot receive instructions to provide heat or hot water.

High Engineer only £180-450

Parts commonly replaced

  • Main PCB
  • Display Interface Module
  • Wiring harness

Related codes

F.00

Your boiler has stopped working because it cannot communicate with the sensor that monitors the temperature of the water leaving the unit.

High Engineer only £90-160

Parts commonly replaced

  • NTC Flow Temperature Sensor
  • Wiring harness
  • PCB

Related codes

F.01

Your boiler has stopped working because it cannot accurately measure the temperature of the water returning to the unit.

High Engineer only £100-£180

Parts commonly replaced

  • NTC Return Temperature Sensor
  • Sensor Wiring Harness

Related codes

F.02

Your boiler has lost the connection to the temperature sensor inside your hot water tank, meaning it cannot currently detect when the water needs heating.

High Engineer only £150-250

Parts commonly replaced

  • Cylinder NTC sensor
  • Wiring harness

Related codes

F.03

Your boiler has lost communication with the built-in hot water storage tank sensor, which means it may struggle to provide consistent hot water.

Medium Engineer only £120-250

Parts commonly replaced

  • actoSTOR cylinder NTC sensor
  • Wiring harness

Related codes

F.10

Your boiler has detected an electrical fault with the internal sensor that monitors the water temperature leaving the unit, causing it to shut down for safety.

High Engineer only £90-160

Parts commonly replaced

  • NTC Flow Temperature Sensor
  • Wiring harness/connector
  • PCB

Related codes

F.11

Your boiler has stopped working because it thinks the water returning to the unit is much hotter than it actually is, causing it to shut down for safety.

High Engineer only £100-£180

Parts commonly replaced

  • Return temperature sensor (NTC thermistor)
  • Internal wiring loom
  • Main PCB

Related codes

F.12

Your boiler has lost the ability to measure the temperature of your hot water cylinder because of a faulty sensor or a wiring issue, meaning it cannot heat your water correctly.

High Engineer only £90-160

Parts commonly replaced

  • Hot water cylinder NTC sensor
  • Wiring harness

Related codes

F.13

Your boiler has detected an electrical fault with the sensor that monitors your hot water tank, meaning it cannot accurately tell if your water is hot enough.

Medium Engineer only £90-160

Parts commonly replaced

  • Domestic Hot Water Cylinder NTC Sensor
  • Wiring Harness

Related codes

F.20

Your boiler has switched itself off because it has reached an unsafe temperature and needs to cool down.

High DIY-safe £100-280

What to check first

  1. Ensure all radiator valves are fully open to allow water to flow.
  2. Check the boiler pressure gauge and top up to 1.5 bar if it is too low.
  3. Press the 'Flame' or 'Reset' button and hold for one second to restart the system.

Parts commonly replaced

  • Circulation Pump
  • Overheat Thermostat
  • Main Heat Exchanger (Flushing)

Related codes

Showing 11–20 of 53
F.22

Your boiler has stopped working because the water pressure inside the system has dropped too low to operate safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually two braided silver hoses or blue levers) underneath the boiler.
  2. Slowly open both valves until you hear water flowing and the pressure gauge reaches between 1.0 and 1.5 bar.
  3. Close both valves tightly and restart the boiler to clear the fault code.

Parts commonly replaced

  • Filling loop valves
  • Pressure sensor
  • Expansion vessel

Related codes

F.23

Your boiler has shut down because there is a significant difference between the water temperature leaving the boiler and the temperature returning to it, usually caused by a circulation problem.

High DIY-safe £100-£350

What to check first

  1. Ensure all radiator valves (TRVs) are fully open
  2. Check that the boiler pressure is between 1.0 and 1.5 bar
  3. Bleed your radiators to remove any trapped air

Parts commonly replaced

  • Circulation pump
  • NTC thermistor (temperature sensor)
  • Magnetic filter (cleaning)

Related codes

F.24

Your boiler has shut down because the internal water temperature is heating up much faster than it can be circulated away, usually meaning the water is stuck or the pump is struggling.

High DIY-safe £150-£350

What to check first

  1. Check that your boiler pressure is between 1.0 and 1.5 bar on the digital display.
  2. Ensure at least two or three radiator valves are turned fully open to allow water flow.
  3. Try resetting the boiler by pressing the flame symbol button to see if the fault clears.

Parts commonly replaced

  • Circulation pump
  • Flow and return thermistors
  • Main heat exchanger (flushing)

Related codes

F.25

Your boiler has shut itself down because the air being pushed out of the chimney pipe has become dangerously hot.

Emergency Engineer only £150-450

Parts commonly replaced

  • Heat exchanger
  • Flue gas NTC sensor
  • Primary heat exchanger cleaning kit
  • Burner seal

Related codes

F.26

Your boiler is unable to open the internal valve that supplies gas to the burner, meaning it cannot ignite to provide heat or hot water.

High Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.27

Your boiler has detected a signal suggesting a flame is present even when it should be turned off, so it has shut itself down as a precaution to ensure your safety.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame sensing electrode

Related codes

F.28

Your boiler is trying to light itself to provide heat, but it is failing to create a flame, likely because it is not getting enough gas or the spark isn't catching.

High DIY-safe £100-350

What to check first

  1. Check that your gas emergency control valve is open and any prepay meters have credit.
  2. Verify if other gas appliances in your home, like a hob, are working correctly.
  3. If it is freezing outside, check if your condensate pipe (the plastic pipe leading outside) is frozen and thaw it with warm water.
  4. Press the Reset button (the flame symbol with a cross) for one second.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Spark Lead
  • Printed Circuit Board (PCB)

Related codes

F.29

Your boiler was working but the flame went out and it cannot manage to light itself back up.

High DIY-safe £100-£350

What to check first

  1. Check if other gas appliances (like a hob) are working to ensure gas is reaching the property
  2. Check if your gas meter has credit and the isolation valve is open
  3. Press the 'Reset' button (indicated by a flame with a line through it) for three seconds

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Spark Lead

Related codes

F.32

Your boiler's fan is unable to spin at the correct speed, which prevents the boiler from safely clearing exhaust fumes and starting the ignition process.

High Engineer only £250-£450

Parts commonly replaced

  • Combustion Fan
  • PCB (Main Control Board)
  • Wiring harness

Related codes

F.42

Your boiler is having trouble identifying its own internal settings due to a connection error between its electronic parts.

High Engineer only £150-300

Parts commonly replaced

  • Coding resistor
  • Printed Circuit Board (PCB)

Related codes

Showing 21–30 of 53
F.49

Your boiler has lost its ability to communicate with its external controls, such as your thermostat, due to an electrical glitch in the internal data wiring.

High Engineer only £100-250

Parts commonly replaced

  • eBUS cable
  • External controls receiver
  • PCB (Printed Circuit Board)

Related codes

F.52

Your boiler is having trouble measuring the air flowing into it, so it has shut down to ensure it operates safely.

High Engineer only £180-350

Parts commonly replaced

  • Mass flow sensor
  • Venturi
  • Wiring harness

Related codes

F.53

Your boiler is struggling to mix the correct amount of gas and air to burn properly, so it has safely shut itself down to prevent issues.

High Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Air pressure switch
  • Gas-air mixture assembly

Related codes

F.54

Your boiler is failing to ignite because it is not receiving enough gas to function properly.

High Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Gas pressure regulator
  • Gas meter

Related codes

F.56

Your boiler has detected an issue with the system that controls the gas and air mixture required to burn fuel safely, so it has shut down to prevent any risk.

Emergency Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Gas valve cable harness
  • PCB (Printed Circuit Board)

Related codes

F.57

Your boiler has temporarily stopped operating to protect itself from a potential hardware fault during its startup sequence.

Medium Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • PCB
  • Wiring harness

Related codes

F.61

Your boiler is unable to correctly control the flow of gas, causing it to shut down for safety purposes.

High Engineer only £250-£550

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.62

Your boiler has detected that the gas valve is not closing as quickly as it should, preventing the unit from shutting down the burner safely.

Emergency Engineer only £250-£550

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

F.64

Your boiler has detected an internal communication error between its electrical sensors and the main control board, causing it to shut down for safety.

High Engineer only £180-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • NTC Temperature Sensors
  • Wiring Loom

Related codes

Showing 31–40 of 53
F.65

Your boiler's internal control board has become too hot and has shut down the system to prevent damage.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Display PCB

Related codes

F.67

Your boiler's electronic control board has detected a confusing signal from the flame sensor, causing the system to shut down for safety.

High Engineer only £280-£450

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Electrode / Flame Sensor

Related codes

F.68

Your boiler is struggling to keep its flame burning steadily, causing it to shut down for safety.

High Engineer only £120-£350

Parts commonly replaced

  • Ionisation electrode
  • Gas valve
  • Burner
  • Ignition lead

Related codes

F.70

Your boiler’s control board has lost its identity settings, meaning the internal computer no longer knows which specific model it is supposed to be operating.

High Engineer only £100-£350

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • User Interface Display Board

Related codes

F.71

Your boiler is struggling to accurately measure the water temperature leaving the unit, usually because a sensor has failed or become disconnected.

High Engineer only £90-160

Parts commonly replaced

  • Flow temperature sensor (NTC)
  • Return temperature sensor (NTC)
  • Wiring harness

Related codes

F.72

Your boiler has detected that the sensors measuring water temperature going in and out are giving conflicting readings, so it has shut down as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Flow NTC sensor
  • Return NTC sensor
  • Sensor wiring harness

Related codes

F.73

Your boiler is struggling to read how much water is in the system because of a sensor issue, which has caused it to stop working for your safety.

High Engineer only £130-220

Parts commonly replaced

  • Digital water pressure sensor
  • Sensor wiring harness

Related codes

F.74

Your boiler's internal sensor has detected that the water pressure is too high or the sensor itself is sending an incorrect reading.

High DIY-safe £120-200

What to check first

  1. Check the digital or manual pressure gauge; if it is above 2.5 bar, you need to reduce the pressure.
  2. Ensure both valves on the external filling loop are tightly closed to prevent more water entering.
  3. Bleed water from a radiator using a bleed key into a container until the pressure gauge returns to between 1.0 and 1.5 bar.

Parts commonly replaced

  • Water pressure sensor
  • Filling loop valve

Related codes

F.75

Your boiler is unable to sense water moving or pressure building when it tries to start up, which has caused it to shut down for safety.

High DIY-safe £180-350

What to check first

  1. Check the pressure gauge and ensure it is between 1.0 and 1.5 bar
  2. If pressure is too low, use the filling loop to top it up
  3. Reset the boiler to see if the fault clears

Parts commonly replaced

  • Water Pressure Sensor
  • Circulation Pump
  • Expansion Vessel

Related codes

F.77

Your boiler is struggling to push waste gases out through the flue or is unable to clear internal condensation water properly.

High Engineer only £120-350

Parts commonly replaced

  • Condensate pump
  • Flue gas non-return flap
  • Wiring harness

Related codes

Showing 41–50 of 53
F.78

Your boiler is having trouble communicating with an external hot water control component, meaning it doesn't know the temperature of the water heading to your taps.

High Engineer only £90-180

Parts commonly replaced

  • DHW NTC Sensor
  • External Link Box
  • Wiring harness

Related codes

F.80

Your boiler is having trouble communicating with an internal sensor that helps regulate hot water temperature, which means your heating or hot water may stop working.

High Engineer only £150-250

Parts commonly replaced

  • Secondary heat exchanger NTC sensor
  • Wiring harness
  • PCB

Related codes

F.81

Your boiler's built-in hot water storage tank is failing to pump water correctly, which means you will likely have no hot water available.

High Engineer only £250-450

Parts commonly replaced

  • actoSTOR charging pump
  • PCB

Related codes

F.83

Your boiler is firing up, but it doesn't detect the water getting hotter quickly enough, so it has shut down to prevent itself from overheating.

High DIY-safe £100-250

What to check first

  1. Check that your boiler pressure is between 1.0 and 1.5 bar on the digital display
  2. Ensure all radiator valves (TRVs) are turned to the highest setting
  3. Top up the water pressure using the filling loop if it is too low

Parts commonly replaced

  • NTC Temperature Sensors
  • Heat Exchanger (Descaling)
  • Circulation Pump

Related codes

F.84

Your boiler is confused because its internal thermometers are giving conflicting readings and don't agree on how hot the water actually is.

High Engineer only £120-£250

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • NTC thermistor
  • Wiring harness

Related codes

F.85

Your boiler has stopped working because its internal thermometers are giving conflicting readings and believe they have been fitted to the wrong pipes.

High Engineer only £90-180

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • NTC cable harness

Related codes

F.90

Your boiler has lost the digital connection to its internal hot water storage tank, meaning it cannot properly coordinate heating the water for your taps.

High Engineer only £150-300

Parts commonly replaced

  • actoSTOR communication cable
  • PCB (Printed Circuit Board)
  • Wiring harness

Related codes

F.91

Your boiler is having trouble communicating with the internal water storage tank, which means your hot water supply may be affected or inconsistent.

High Engineer only £150-300

Parts commonly replaced

  • actoSTOR interface board
  • Wiring harness
  • Tank temperature sensor

Related codes

F.92

Your boiler's internal computer is receiving the wrong information about its own identity, preventing it from running safely.

High Engineer only £100-£250

Parts commonly replaced

  • Coding Resistor
  • PCB (Printed Circuit Board)

Related codes

F.93

Your boiler has detected that the fuel-to-air mixture is incorrect, which means it cannot burn gas safely or efficiently.

Emergency Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Venturi
  • Burner seal

Related codes

Showing 51–53 of 53
F22

Your boiler has stopped working because the water pressure is too low for it to operate safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop handles (usually two blue or black taps) underneath the boiler.
  2. Slowly turn both handles 90 degrees to allow water into the system while watching the pressure gauge.
  3. Close both handles fully once the pressure reaches between 1.0 and 1.5 bar.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure sensor
F70

Your boiler's internal computer has forgotten its identity settings, preventing it from starting up correctly.

High Engineer only £150-300

Parts commonly replaced

  • User Interface PCB
  • Main PCB

Related codes

S.57

Your boiler is temporarily pausing its operation to allow internal parts to cool down or stabilize, which is a normal safety feature to prevent overheating.

Low Engineer only

57 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

D.000 Diagnostic Your boiler is currently set to run at a lower power level than its maximum capacity to save energy or match your home's heat demand. P.00 Diagnostic Your boiler is currently running an automatic program to remove trapped air from the system, which usually happens during startup or after maintenance. P.01 Diagnostic Your boiler has failed while running a specific test used for commissioning or high-power performance checks. P.02 Diagnostic Your boiler is not in a fault state; it is simply running a pre-programmed test to check how it performs at its lowest power setting. P.06 Diagnostic Your boiler is currently running a self-check program to fill the heating system with water and is not experiencing a permanent fault. S.00 Status Your boiler is currently in standby mode because it has not received a request for heating or hot water from your thermostat or taps. S.01 Status Your boiler is performing a normal startup procedure by clearing out the combustion chamber before it begins heating your home. S.1 Status Your boiler is preparing to ignite but is stuck at the stage where the internal fan is spinning up to clear the combustion chamber. S.02 Status Your boiler is simply preparing its internal pump before starting the heating process, which is a normal part of its operation. S.2 Status Your boiler is currently moving water through the system after a heating or hot water cycle to cool down the internal components safely. S.03 Status Your boiler is currently busy performing its normal start-up sequence to fire up the burner for heating. S.04 Status Your boiler is currently working perfectly and is simply telling you that it is busy heating your radiators. S.05 Status Your boiler is briefly keeping the internal fan and pump running to safely cool down the heat exchanger after a heating cycle. S.06 Status Your boiler is temporarily running the internal fan to cool the system down after the heating has switched off. S.07 Status Your boiler is briefly running the pump after heating your radiators to safely move residual heat away from the unit. S.08 Status Your boiler is taking a short, normal break after finishing a heating cycle to prevent overheating and ensure everything cools down properly. S.10 Status Your boiler is simply letting you know that it is currently busy heating up water for your taps or shower. S.11 Status Your boiler is simply preparing its internal airflow to heat your water, which is a normal part of its startup process and not an error at all. S.13 Status Your boiler is currently just starting the process to heat your water, so it is working normally and does not have a fault. S.14 Status Your boiler is working exactly as it should and is currently heating up the water for your taps. S.15 Status Your boiler is simply performing a routine cooling-down process after you last used hot water, and there is no fault with your system. S.16 Status Your boiler is currently cooling down its internal components after you have finished using hot water, which is a normal part of its shutdown process. S.17 Status Your boiler is simply finishing its cooling cycle after you have finished using hot water, and no action is required. S.20 Status Your boiler is not broken; it is simply letting you know that it has received a request to provide hot water and is currently preparing to deliver it. S.21 Status Your boiler is briefly checking its fan and clearing the system before it starts heating your hot water. S.22 Status Your boiler is not broken; it is simply performing a routine preparation step to ensure everything is ready before it begins heating your water. S.23 Status Your boiler is currently preparing the burner to provide hot water, which is a normal part of its operation. S.24 Status Your boiler is working normally and is currently heating up your hot water. S.25 Status Your boiler is briefly cooling itself down after providing hot water and will resume normal operation in a few moments. S.26 Status Your boiler is simply running its internal fan for a short period to cool down after you have finished using hot water. S.27 Status Your boiler is briefly running the internal pump after providing hot water to help cool down the internal components. S.28 Status Your boiler has temporarily stopped the burner because it has reached the required temperature for hot water and is taking a short break to prevent overheating. S.30 Status Your boiler is working fine, but your external room thermostat or timer is telling it not to turn the heating on right now. S.31 Status Your boiler is working correctly but is currently ignoring heating requests because it is either set to summer mode or is waiting for a command from your external thermostat. S.32 Status Your boiler is struggling to start because the internal fan is not spinning at the correct speed required for a safe ignition. S.34 Status Your boiler has sensed the temperature is very cold and is automatically running to prevent the internal pipes from freezing. S.39 Status Your boiler has received a signal from your underfloor heating system to stop running, likely because a safety thermostat has triggered to prevent the floor from getting too hot. S.40 Status Your boiler has detected a minor performance issue and is operating in a temporary energy-saving mode to ensure it keeps running safely while limiting output. S.41 Status Your boiler has detected that there is too much water in the system, which puts extra stress on the pipes and components. S.42 Status Your boiler has detected that a safety flap in the flue pipe is stuck closed, preventing exhaust gases from escaping. S.46 Status Your boiler has detected very cold temperatures and has automatically turned itself on at a low setting to prevent the internal pipes from freezing. S.53 Status Your boiler has temporarily stopped working because it has detected that water is the not moving through the system quickly enough to safely carry heat away. S.54 Status Your boiler has paused because it detects that water is not circulating quickly enough, often due to low pressure or an air pocket. S.58 Status Your boiler has temporarily reduced its power because it is detecting unusual air movement or wind pressure in the flue system, likely due to external weather conditions. S.61 Status Your boiler's computer has detected a configuration mismatch and cannot confirm it is safely set up for your home's gas supply. S.62 Status Your boiler has detected that the fuel and air mixture used to heat your home is not balanced correctly, meaning it cannot operate safely or efficiently. S.63 Status Your boiler has detected that the fuel-to-air mix is incorrect, which means it cannot burn gas safely or efficiently. S.76 Status Your boiler has stopped working because the water pressure inside the heating system has dropped too low. S.96 Status Your boiler is temporarily paused because it is running a self-diagnostic check on its internal temperature sensors to ensure they are working correctly. S.97 Diagnostic Your boiler is currently performing an internal health check on its sensors and has temporarily paused heating and hot water to ensure everything is functioning safely. S.98 Status Your boiler is temporarily paused because it has detected a potential issue with its internal sensors while performing a self-test. T.02 Diagnostic Your boiler is struggling to switch between providing hot water and heating your radiators because an internal valve is stuck or malfunctioning. T.03 Diagnostic Your boiler's fan is struggling to start or run at the correct speed, which is preventing the boiler from firing up for safety. T.04 Diagnostic Your boiler is struggling to move heated water to your hot water cylinder, which means you may not have any hot water. T.05 Diagnostic Your boiler's internal pump is having trouble moving water through the system, which is preventing it from providing heating or hot water. T.06 Diagnostic Your boiler is struggling to push water around your radiators because an external pump is not working as expected. T.08 Diagnostic Your boiler is currently completing a routine check of its burner system while it is in the process of starting up.