Common problems guide

The most common Vaillant Turbomax 824/828 problems

The faults most likely to send a Vaillant Turbomax 824/828 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
25 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
F.22 High DIY-safe

Your boiler has detected that there is either too little water inside the system or that the internal pump is failing to move the water around as it should.

What to try first

Check your boiler pressure gauge; if it is below 1 bar, use the filling loop to top it up to between 1 and 1.5 bar.Once pressure is restored, reset the boiler using the reset button or by turning the power off and on again.If the pressure is fine, try tapping the pump housing gently with a screwdriver handle to see if it is merely stuck, but do not open the casing.

Est. cost
£120-250
Parts
Circulating pump, Pressure sensor, Filling loop
Full guide for F.22
02
F.24 High DIY-safe

Your boiler has detected that the water is heating up far too quickly, likely because there is air trapped inside or the pump is struggling to circulate water properly.

What to try first

Check your system pressure gauge; if it is below 1 bar, top it up using the filling loopBleed all radiators in the house starting from the ground floor up to the top floor to release trapped airRestart the boiler to see if it clears the fault

Est. cost
£120-300
Parts
Central heating pump, NTC temperature sensor, Automatic air vent
Full guide for F.24
03
F.00 High Engineer

Your boiler is unable to read the temperature of the water flowing out of it because a sensor or its connection has failed, causing the system to stop working as a precaution.

Est. cost
£120-220
Parts
Flow NTC sensor, Wiring harness
Full guide for F.00
04
F.01 High Engineer

Your boiler has lost the signal from the sensor that monitors the temperature of water returning to it, meaning it cannot safely regulate its heat.

Est. cost
£120-220
Parts
Return NTC sensor, Wiring harness
Full guide for F.01
05
F.10 High Engineer

Your boiler has detected a faulty electrical signal from its internal temperature sensor, causing it to shut down to prevent potential overheating.

Est. cost
£120-200
Parts
Flow NTC thermistor, Wiring harness
Full guide for F.10
06
F.11 High Engineer

Your boiler has detected an electrical fault in a temperature sensor that monitors the water returning to the system, causing it to shut down for safety.

Est. cost
£120-220
Parts
Return NTC sensor, Wiring harness
Full guide for F.11

on the Vaillant Turbomax 824/828

Circulating pumpPressure sensorFilling loopCentral heating pumpNTC temperature sensorAutomatic air vent

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Vaillant shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 25-code list for the Vaillant Turbomax 824/828