Vokera Evolve Fault codes & diagnostics

19 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

CombiSystem Natural GasLPG 18-42 kW 2017-present
GC Numbers 47-094-0847-094-0947-094-1047-094-1141-094-1241-094-1341-094-14

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
4 Emergency 13 High 2 Medium

All 19 documented codes

Tap any card for details

4070

Your boiler has detected that the water temperature is too high and has shut down to prevent damage to its internal components.

High Engineer only £120-280

Parts commonly replaced

  • Flow Thermistor
  • Return Thermistor
  • Circulation Pump
  • Main Heat Exchanger
E10

Your boiler has stopped working because it failed to light the flame after several attempts, usually due to a lack of gas supply or an ignition problem.

High DIY-safe £90-280

What to check first

  1. Check if other gas appliances in your home, like a hob, are working to confirm gas supply.
  2. Verify that your gas meter has credit if you use a pre-payment meter.
  3. Press the Reset button on the boiler control panel to see if the system restarts.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Flame sensing probe
  • Printed Circuit Board (PCB)
E011

Your boiler has detected a flame when there shouldn't be one, or the sensor incorrectly thinks a fire is lit, causing it to shut down for safety.

High Engineer only £120-300

Parts commonly replaced

  • Ionisation Probe
  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

E020

Your boiler has shut down because it has reached an unsafe temperature, triggered by a safety sensor that prevents the unit from overheating.

High DIY-safe £120-280

What to check first

  1. Check that all radiator valves are fully open to allow water to circulate.
  2. Ensure your system pressure is topped up to between 1 and 1.5 bar.
  3. Turn the boiler off and on again, or press the 'Reset' button to clear the lockout once the system has cooled down.

Parts commonly replaced

  • Limit thermostat (Overheat sensor)
  • Circulation pump
  • Main Heat Exchanger (Flushing)
E030

Your boiler has stopped working because the fan that removes waste gases is not spinning or communicating correctly with the system.

High Engineer only £250-£450

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness
E040

Your boiler has detected that the water pressure is either too low or the sensor that monitors it is not communicating correctly.

High DIY-safe £90-180

What to check first

  1. Locate the pressure gauge on the front of the boiler or via the digital screen.
  2. If the pressure is below 1 bar, use the filling loop underneath the boiler to carefully top it up to 1.5 bar.
  3. Restart the boiler to see if the error clears once the pressure is stable.

Parts commonly replaced

  • Water pressure transducer
  • Filling loop valves

Related codes

E041

Your boiler has detected that the water pressure is incorrect or the sensor that monitors it is not communicating properly.

High DIY-safe £120-210

What to check first

  1. Check the pressure gauge on the front of the boiler; it should be between 1 and 1.5 bar.
  2. If the pressure is too low, use the filling loop valves to top up the system until the gauge reaches 1.2 bar.
  3. Reset the boiler to see if the fault clears.

Parts commonly replaced

  • Water pressure transducer
  • Filling loop valve

Related codes

E042

Your boiler has lost the ability to measure the water pressure accurately, which has caused it to stop running for safety.

High Engineer only £130-210

Parts commonly replaced

  • Water Pressure Transducer
  • Wiring Harness

Related codes

E058

Your boiler has detected an issue with its incoming electrical power supply, which is often caused by a voltage surge or a fault on the main circuit board.

High Engineer only £180-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Electrical wiring harness

Related codes

E060

Your boiler is struggling to accurately measure the temperature of your hot water, which usually means your taps will only run cold.

High Engineer only £90-160

Parts commonly replaced

  • DHW NTC Thermistor
  • Connecting wiring harness

Related codes

E065

Your boiler has detected an electrical issue with the part that controls how much gas is burned, causing the system to shut down for safety.

High Engineer only £140-£350

Parts commonly replaced

  • Gas valve modulator coil
  • Gas valve assembly
  • Main PCB

Related codes

E077

Your boiler has detected an issue with the sensor that monitors the water temperature in your main heating circuit, which may prevent your radiators from warming up correctly.

Medium Engineer only £90-180

Parts commonly replaced

  • Main zone NTC thermistor
  • Wiring harness
  • Control PCB

Related codes

E080

Your boiler has detected that the water returning from your radiators is too hot or the temperature difference is incorrect, causing the system to shut down for safety.

High Engineer only £120-280

Parts commonly replaced

  • Return thermistor/NTC sensor
  • Circulation pump
  • Main heat exchanger

Related codes

E085

Your boiler has detected an unsafe level of carbon monoxide or improper combustion, which means it has shut down to protect your safety.

Emergency Engineer only £150-450

Parts commonly replaced

  • Gas Valve
  • Electrode
  • Burner
  • Main PCB

Related codes

E086

Your boiler has detected a blockage in the flue pipe that is preventing waste gases from safely exiting your home.

Emergency Engineer only £120-350

Parts commonly replaced

  • Flue terminal
  • Fan assembly
  • Air pressure switch
E090

Your boiler has sensed that the exhaust fumes are getting too hot and has shut down as a safety precaution to prevent damage.

High Engineer only £120-£350

Parts commonly replaced

  • Main Heat Exchanger
  • Flue NTC Thermistor
  • Burner Door Insulation

Related codes

E091

Your boiler has detected that the main part responsible for heating your water is becoming blocked or dirty and needs a professional service.

Medium Engineer only £100-250

Parts commonly replaced

  • Heat exchanger cleaning fluid
  • Heat exchanger seals
  • Primary heat exchanger

Related codes

E094

Your boiler has detected an unsafe level of carbon monoxide or improper combustion, which means it has shut down to protect your safety.

Emergency Engineer only £150-450

Parts commonly replaced

  • Gas Valve
  • Electrode
  • Burner
  • Main PCB

Related codes

E095

Your boiler has detected an unsafe level of carbon monoxide or improper combustion, which means it has shut down to protect your safety.

Emergency Engineer only £150-450

Parts commonly replaced

  • Gas Valve
  • Electrode
  • Burner
  • Main PCB

Related codes